Attention should be paid to the maintenance plan of rotary dehumidifier

Author:Lianzhong | Release time:2021-06-17

With the improvement of living standard, people have higher and higher requirements for health. More and more families begin to use the wheel dehumidifier. The runner dehumidifier is seasonal product, and it is more important to maintain it carefully. Proper maintenance can greatly reduce the dehumidification effect of the dehumidifier of the runner, reduce the occurrence of the failure and prolong the service life. The following are some methods for the correct use, maintenance and repair of the runner dehumidifier.

The humidity setting value of the runner dehumidifier is not a fixed parameter, and should be set according to the customer requirements, region, season and indoor humidity sources. Generally, when there are less activities such as rest and sleep, the relative humidity of the room is about 60 points RH, which makes people feel comfortable. If the set humidity is too low, it will not only make people feel dry, but also cause frequent start and stop of compressor due to the large difference of indoor and outdoor humidity, shorten the service life of the runner dehumidifier and increase energy consumption.

Attention should be paid to the maintenance plan of rotary dehumidifier

Bixu can only be used after the equipment of the runner dehumidifier is moved, and bixu can be used after 4-6 hours of static swing. Because the compressor pipeline in dehumidification equipment contains refrigerant, bixu can only move 2-4 hours to return to its original position to achieve the best dehumidification effect of Zui.

The wheel dehumidifier should be in room Zhangyang. The inlet and outlet of the runner dehumidifier shall not be blocked and the screen shall be clean. When the ambient temperature is lower than 15 ℃, the droplets attached to the evaporator surface freeze, which weakens the function of the wheel dehumidifier. If the ambient temperature is more than 40 ℃, the pressure in the system will increase, which will cause the compressor overload protector to be cut off. At this time, the overload protector should cut off the circuit, otherwise it will damage the compressor motor. Therefore, the optimum temperature range of Zui of the runner dehumidifier is 5 ℃ ~38 ℃, and the microcomputer controlled wheel dehumidifier has the function of automatic defrosting, and the temperature range can reach 5 ℃ ~40 ℃. If the humidity in the atmosphere is lower than 30 points, it is too dry and uncomfortable, so the humidity should be controlled within 50 points to 60 points. When using, close the doors and windows as much as possible to achieve indoor dehumidification effect. The fuselage shall be placed flat and not inclined or placed horizontally to avoid machine failure or abnormal sound. The water storage of the runner dehumidifier is too full. To avoid overflow, please pull off the power plug first during operation and pour the water into the water storage tank.

Attention should be paid to the maintenance plan of rotary dehumidifier

Clean air filter regularly (about once in two weeks) to keep the efficiency and life of dehumidification and dust removal of the runner dehumidifier. It can effectively improve the dust removal effect of dulaxin wheel dehumidifier and improve the air quality. Cleaning the radiator of outdoor unit regularly can effectively improve the heat transfer coefficient and efficiency, and improve the working efficiency of dulaxin wheel dehumidifier. The screen can be cleaned with water below 40 ℃, Zui can be cleaned with detergent, cleaned with water after dust removal, and then put back to the machine after drying. When cleaning the machine body, wipe it with a damp cloth to avoid direct watering to avoid damaging the electrical insulation. The adhesive on the surface of the body can be cleaned with soap water. Avoid spraying gasoline, oil essence, solvent or insecticide to avoid paint removal or discoloration. Do not use a stick or wire to squeeze the inside of the machine to avoid failure or danger. The runner dehumidifier is not powered up or used for a long time. Please unplug the power plug during travel to keep the service life of the wheel dehumidifier.

After a long time of use, the circuit and control elements in the unit will aging to different degrees, and will cause damage to the unit and human body in serious cases. The circuit of the runner dehumidifier shall be regularly checked by professional personnel, the aging parts shall be replaced and the coolant shall be supplemented. The damage to the unit and human body caused by aging parts can be prevented, and the runner dehumidifier can be in good working condition.

When the runner dehumidifier is not used outdoors or for a long time, it is necessary to cover it with protective cover to avoid sun, rain and dust. It is difficult to clean and maintain the dehumidifier in the future.